1 查看故障硬件具体位置

1.1  查看日志

XSCF> showstatus

*   CMU#0 Status:Degraded;

*       MEM#00A Status:Degraded;

*       MEM#01A Status:Faulted;

*       MEM#02A Status:Deconfigured;

*       MEM#03A Status:Deconfigured;

*       MEM#10A Status:Deconfigured;

*       MEM#11A Status:Deconfigured;

*       MEM#12A Status:Deconfigured;

*       MEM#13A Status:Deconfigured;

*   XSCFU_B#1 Status:Faulted;

XSCF>

 

1.2 故障控制器

*   XSCFU_B#1 Status:Faulted

1.3 故障内存

*       MEM#00A Status:Degraded;

*       MEM#01A Status:Faulted;

 

1.4 故障图片

 

面板故障灯:

 image.png

 

控制器故障灯:

 image.png

内存故障灯:

image.png 

2 换控制器

2.1 进入换件流程

XSCF> replacefru

----------------------------------------------------------------------

Maintenance/Replacement Menu

Please select a type of FRU to be replaced.

 

1. CMU/IOU    (CPU Memory Board Unit/IO Unit)

2. FAN        (Fan Unit)

3. PSU        (Power Supply Unit)

4. XSCFU      (Extended System Control Facility Unit)

5. DDC_A      (DDC for BP_A)

----------------------------------------------------------------------

Select [1-5|c:cancel] :4

 

2.2 选择控制器

 

----------------------------------------------------------------------

Maintenance/Replacement Menu

Please select an XSCF to be replaced.

 

No. FRU             Status

--- --------------- ------------------

 1. XSCFU_B#0       Active

 2. XSCFU_B#1       Faulted

----------------------------------------------------------------------

Select [1,2|b:back] :2

 

2.3 选择故障控制器

You are about to replace XSCFU_B#1.

Do you want to continue?[r:replace|c:cancel] :r

 

Please confirm the Ready LED is not lit and that the Check LED is

blinking.

If this is the case, please replace XSCFU_B#1.

2.4 换故障控制

 

故障件

image.png 

换完后状态

image.png


2.5  还完后选择完成

After replacement has been completed, please select[f:finish] :f

 

2.6 等待同步数据和维码升级

Waiting for XSCFU_B#1 to enter ready state.

[This operation may take up to 35 minute(s)]

(progress scale reported in seconds)

   0.....  30.....  60.....  90..... 120..... 150..... 180..... 210.....

 240..... 270..... 300..... 330..... 360..... 390..... 420done

 

Updating the firmware of XSCFU_B#1.

[This operation may take up to 60 minute(s)]

(progress scale reported in seconds)

   0.....  30.....  60.....  90..... 120..... 150..... 180..... 210.....

 240..... 270..... 300..... 330..... 360..... 390..... 420..... 450.....

 480..... 510..... 540..... 570..... 600..... 630..... 660..... 690.....

 720..... 750..... 780..... 810..... 840..... 870..... 900..... 930.....

 960..... 990.....1020.....1050.....1080.....1110.....1140.....1170.....

1200.....1230.done

 

----------------------------------------------------------------------

Maintenance/Replacement Menu

Status of the replaced FRU.

 

FRU           Status

------------- --------

XSCFU_B#1     Standby

 

 

2.7  选择升级完成

 

The replacement of XSCFU_B#1 has completed normally.[f:finish] :f

----------------------------------------------------------------------

Maintenance/Replacement Menu

Please select a type of FRU to be replaced.

 

1. CMU/IOU    (CPU Memory Board Unit/IO Unit)

2. FAN        (Fan Unit)

3. PSU        (Power Supply Unit)

4. XSCFU      (Extended System Control Facility Unit)

5. DDC_A      (DDC for BP_A)

----------------------------------------------------------------------

Select [1-5|c:cancel] :c

 

XSCF>

 

2.8  查看版本

XSCF> version -c xcp

XSCF#0 (Active )

XCP0 (Current): 1121

XCP1 (Reserve): 1121

XSCF#1 (Standby)

XCP0 (Current): 1121

XCP1 (Reserve): 1121

XSCF>

XSCF>


3 换内存

3.1 进入换件流程

XSCF> replacefru

----------------------------------------------------------------------

Maintenance/Replacement Menu

Please select a type of FRU to be replaced.

 

1. CMU/IOU    (CPU Memory Board Unit/IO Unit)

2. FAN        (Fan Unit)

3. PSU        (Power Supply Unit)

4. XSCFU      (Extended System Control Facility Unit)

5. DDC_A      (DDC for BP_A)

----------------------------------------------------------------------

Select [1-5|c:cancel] :1

 

3.2 选择CMUIOU

----------------------------------------------------------------------

Maintenance/Replacement Menu

Please select whether to replace a CMU only, an IOU only,

or both a CMU and an IOU.

 

 1. Replace CMU only.

 2. Replace IOU only.

 3. Replace both CMU and IOU.

----------------------------------------------------------------------

Select [1-3|b:back] :1

 

3.3 选择内存板CMU

----------------------------------------------------------------------

Maintenance/Replacement Menu

Please select a CMU to be replaced.

 

                  DomainID

No. FRU           XSB#0 XSB#1 XSB#2 XSB#3 Power Status

--- ------------- ----------------------- ----- ---------------

 1. CMU#0             0     0     0     0  Off   Degraded *

 2. CMU#1             0     0     0     0  Off   Normal

 3. CMU#2             1     1     1     1  Off   Normal

 4. CMU#3             1     1     1     1  Off   Normal

----------------------------------------------------------------------

Select [1-4|b:back] :1

 

3.4 选择0号内存板

 

----------------------------------------------------------------------

Maintenance/Replacement Menu

Status of the selected FRU.

 

FRU           Status

------------- --------

CMU#0         Degraded

    CPUM#0    Normal

    CPUM#1    Normal

    CPUM#2    Normal

    CPUM#3    Normal

    MEM#00A   Degraded

    MEM#01A   Faulted

    MEM#02A   Normal

    MEM#03A   Normal

    MEM#10A   Normal

    MEM#11A   Normal

    MEM#12A   Normal

    MEM#13A   Normal

    MEM#20A   Normal

    MEM#21A   Normal

    MEM#22A   Normal

    MEM#23A   Normal

    MEM#30A   Normal

    MEM#31A   Normal

    MEM#32A   Normal

    MEM#33A   Normal

----------------------------------------------------------------------

You are about to replace CMU#0.

Do you want to continue?[r:replace|c:cancel] :r

 

3.5 确认更换内存板

 

 

Please confirm the Ready LED is not lit and that the Check LED is

blinking.

If this is the case, please replace CMU#0.

 

3.6 换故障内存

 

等待主板掉电就可以换了

image.png

image.png

image.png

image.png


3.7 换完结束

 

After replacement has been completed, please select[f:finish] :f

 

----------------------------------------------------------------------

Maintenance/Replacement Menu

Status of the selected FRU.

 

FRU           Status

------------- --------

CMU#0         Normal

    CPUM#0    Normal

    CPUM#1    Normal

    CPUM#2    Normal

    CPUM#3    Normal

    MEM#00A   Normal

    MEM#01A   Normal

    MEM#02A   Normal

    MEM#03A   Normal

    MEM#10A   Normal

    MEM#11A   Normal

    MEM#12A   Normal

    MEM#13A   Normal

    MEM#20A   Normal

    MEM#21A   Normal

    MEM#22A   Normal

    MEM#23A   Normal

    MEM#30A   Normal

    MEM#31A   Normal

    MEM#32A   Normal

    MEM#33A   Normal

----------------------------------------------------------------------

The replacement of CMU#0 has completed normally.[f:finish] :f

 

----------------------------------------------------------------------

Maintenance/Replacement Menu

Please select a type of FRU to be replaced.

 

1. CMU/IOU    (CPU Memory Board Unit/IO Unit)

2. FAN        (Fan Unit)

3. PSU        (Power Supply Unit)

4. XSCFU      (Extended System Control Facility Unit)

5. DDC_A      (DDC for BP_A)

----------------------------------------------------------------------

Select [1-5|c:cancel] :c

 

4 查看主机日志

XSCF> showstatus

No failures found in System Initialization.

XSCF>