1 查看故障硬件具体位置
1.1 查看日志
XSCF> showstatus
* CMU#0 Status:Degraded;
* MEM#00A Status:Degraded;
* MEM#01A Status:Faulted;
* MEM#02A Status:Deconfigured;
* MEM#03A Status:Deconfigured;
* MEM#10A Status:Deconfigured;
* MEM#11A Status:Deconfigured;
* MEM#12A Status:Deconfigured;
* MEM#13A Status:Deconfigured;
* XSCFU_B#1 Status:Faulted;
XSCF>
1.2 故障控制器
* XSCFU_B#1 Status:Faulted
1.3 故障内存
* MEM#00A Status:Degraded;
* MEM#01A Status:Faulted;
1.4 故障图片
面板故障灯:
控制器故障灯:
内存故障灯:
2 换控制器
2.1 进入换件流程
XSCF> replacefru
----------------------------------------------------------------------
Maintenance/Replacement Menu
Please select a type of FRU to be replaced.
1. CMU/IOU (CPU Memory Board Unit/IO Unit)
2. FAN (Fan Unit)
3. PSU (Power Supply Unit)
4. XSCFU (Extended System Control Facility Unit)
5. DDC_A (DDC for BP_A)
----------------------------------------------------------------------
Select [1-5|c:cancel] :4
2.2 选择控制器
----------------------------------------------------------------------
Maintenance/Replacement Menu
Please select an XSCF to be replaced.
No. FRU Status
--- --------------- ------------------
1. XSCFU_B#0 Active
2. XSCFU_B#1 Faulted
----------------------------------------------------------------------
Select [1,2|b:back] :2
2.3 选择故障控制器
You are about to replace XSCFU_B#1.
Do you want to continue?[r:replace|c:cancel] :r
Please confirm the Ready LED is not lit and that the Check LED is
blinking.
If this is the case, please replace XSCFU_B#1.
2.4 换故障控制
故障件
换完后状态
2.5 还完后选择完成
After replacement has been completed, please select[f:finish] :f
2.6 等待同步数据和维码升级
Waiting for XSCFU_B#1 to enter ready state.
[This operation may take up to 35 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90..... 120..... 150..... 180..... 210.....
240..... 270..... 300..... 330..... 360..... 390..... 420done
Updating the firmware of XSCFU_B#1.
[This operation may take up to 60 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90..... 120..... 150..... 180..... 210.....
240..... 270..... 300..... 330..... 360..... 390..... 420..... 450.....
480..... 510..... 540..... 570..... 600..... 630..... 660..... 690.....
720..... 750..... 780..... 810..... 840..... 870..... 900..... 930.....
960..... 990.....1020.....1050.....1080.....1110.....1140.....1170.....
1200.....1230.done
----------------------------------------------------------------------
Maintenance/Replacement Menu
Status of the replaced FRU.
FRU Status
------------- --------
XSCFU_B#1 Standby
2.7 选择升级完成
The replacement of XSCFU_B#1 has completed normally.[f:finish] :f
----------------------------------------------------------------------
Maintenance/Replacement Menu
Please select a type of FRU to be replaced.
1. CMU/IOU (CPU Memory Board Unit/IO Unit)
2. FAN (Fan Unit)
3. PSU (Power Supply Unit)
4. XSCFU (Extended System Control Facility Unit)
5. DDC_A (DDC for BP_A)
----------------------------------------------------------------------
Select [1-5|c:cancel] :c
XSCF>
2.8 查看版本
XSCF> version -c xcp
XSCF#0 (Active )
XCP0 (Current): 1121
XCP1 (Reserve): 1121
XSCF#1 (Standby)
XCP0 (Current): 1121
XCP1 (Reserve): 1121
XSCF>
XSCF>
3 换内存
3.1 进入换件流程
XSCF> replacefru
----------------------------------------------------------------------
Maintenance/Replacement Menu
Please select a type of FRU to be replaced.
1. CMU/IOU (CPU Memory Board Unit/IO Unit)
2. FAN (Fan Unit)
3. PSU (Power Supply Unit)
4. XSCFU (Extended System Control Facility Unit)
5. DDC_A (DDC for BP_A)
----------------------------------------------------------------------
Select [1-5|c:cancel] :1
3.2 选择CMU和IOU
----------------------------------------------------------------------
Maintenance/Replacement Menu
Please select whether to replace a CMU only, an IOU only,
or both a CMU and an IOU.
1. Replace CMU only.
2. Replace IOU only.
3. Replace both CMU and IOU.
----------------------------------------------------------------------
Select [1-3|b:back] :1
3.3 选择内存板CMU
----------------------------------------------------------------------
Maintenance/Replacement Menu
Please select a CMU to be replaced.
DomainID
No. FRU XSB#0 XSB#1 XSB#2 XSB#3 Power Status
--- ------------- ----------------------- ----- ---------------
1. CMU#0 0 0 0 0 Off Degraded *
2. CMU#1 0 0 0 0 Off Normal
3. CMU#2 1 1 1 1 Off Normal
4. CMU#3 1 1 1 1 Off Normal
----------------------------------------------------------------------
Select [1-4|b:back] :1
3.4 选择0号内存板
----------------------------------------------------------------------
Maintenance/Replacement Menu
Status of the selected FRU.
FRU Status
------------- --------
CMU#0 Degraded
CPUM#0 Normal
CPUM#1 Normal
CPUM#2 Normal
CPUM#3 Normal
MEM#00A Degraded
MEM#01A Faulted
MEM#02A Normal
MEM#03A Normal
MEM#10A Normal
MEM#11A Normal
MEM#12A Normal
MEM#13A Normal
MEM#20A Normal
MEM#21A Normal
MEM#22A Normal
MEM#23A Normal
MEM#30A Normal
MEM#31A Normal
MEM#32A Normal
MEM#33A Normal
----------------------------------------------------------------------
You are about to replace CMU#0.
Do you want to continue?[r:replace|c:cancel] :r
3.5 确认更换内存板
Please confirm the Ready LED is not lit and that the Check LED is
blinking.
If this is the case, please replace CMU#0.
3.6 换故障内存
等待主板掉电就可以换了
3.7 换完结束
After replacement has been completed, please select[f:finish] :f
----------------------------------------------------------------------
Maintenance/Replacement Menu
Status of the selected FRU.
FRU Status
------------- --------
CMU#0 Normal
CPUM#0 Normal
CPUM#1 Normal
CPUM#2 Normal
CPUM#3 Normal
MEM#00A Normal
MEM#01A Normal
MEM#02A Normal
MEM#03A Normal
MEM#10A Normal
MEM#11A Normal
MEM#12A Normal
MEM#13A Normal
MEM#20A Normal
MEM#21A Normal
MEM#22A Normal
MEM#23A Normal
MEM#30A Normal
MEM#31A Normal
MEM#32A Normal
MEM#33A Normal
----------------------------------------------------------------------
The replacement of CMU#0 has completed normally.[f:finish] :f
----------------------------------------------------------------------
Maintenance/Replacement Menu
Please select a type of FRU to be replaced.
1. CMU/IOU (CPU Memory Board Unit/IO Unit)
2. FAN (Fan Unit)
3. PSU (Power Supply Unit)
4. XSCFU (Extended System Control Facility Unit)
5. DDC_A (DDC for BP_A)
----------------------------------------------------------------------
Select [1-5|c:cancel] :c
4 查看主机日志
XSCF> showstatus
No failures found in System Initialization.
XSCF>